GuideOpen
Analytical Procedure Validation Protocol
Every bracketed field is a decision to make and record before data collection. planvalidation.py --protocol generates a framework-specific version of this document with the required characteristics already listed.
Analytical Procedure Validation Protocol
Every bracketed field is a decision to make and record before data collection. plan_validation.py --protocol generates a framework-specific version of this document with the required characteristics already listed.| Field | Value |
|---|---|
| Protocol number / version | [ ] |
| Analytical procedure identifier and version | [ ] |
| Product / analyte / matrix | [ ] |
| Measured quality attribute | [ ] assay / impurity (quantitative) / impurity (limit) / identity / other |
| Governing framework and section | [ ] |
| Regional expectation confirmed with | [ ] |
| Related development report (ICH Q14) | [ ] |
| Author / date | [ ] |
| Technical reviewer / date | [ ] |
| Quality unit approval / date | [ ] |
1. Intended purpose and analytical target profile
- Measurand and reporting unit: [ ]
- Decision the result supports: [ ] release / stability / in-process / clinical / other
- Specification or reporting limits served: [ ]
- Required reportable range, derived from the specification: [ ]
- Performance characteristics and criteria (formal ATP optional under Q14): [ ]
2. Pre-stated acceptance criteria
State an appropriate criterion and its justification for every characteristic to be validated; identity or specificity criteria need not always be numeric. A criterion with no justification traceable to the specification, the ATP, or development data is not defensible.
| Characteristic | Criterion | Justification | Framework reference |
|---|---|---|---|
| Specificity / selectivity | [ ] | [ ] | [ ] |
| Response (calibration model) | [ ] | [ ] | [ ] |
| Lower range limit (DL / QL) | [ ] | [ ] | [ ] |
| Accuracy | [ ] | [ ] | [ ] |
| Repeatability | [ ] | [ ] | [ ] |
| Intermediate precision | [ ] | [ ] | [ ] |
| Combined accuracy and precision, if used | [ ] | [ ] | [ ] |
- Interval to be reported alongside accuracy and precision: [ ] confidence level [ ]
- Does the criterion apply to the point estimate or to the whole interval? [ ]
3. Study design
| Characteristic | Levels | Replicates | Runs / days / analysts / instruments |
|---|---|---|---|
| Response | [ ] (minimum 5 for ICH Q2(R2)) | [ ] | [ ] |
| Accuracy | [ ] | [ ] | [ ] |
| Repeatability | [ ] | [ ] | [ ] |
| Intermediate precision | [ ] | [ ] | [ ] |
| Lower range limit | [ ] | [ ] | [ ] |
- Replicate count matches the routine reportable result: [ ] yes / [ ] justified deviation: [ ]
- Calibration model and weighting, fixed in advance: [ ] unweighted / 1/x / 1/x² / non-linear / multivariate
- Randomisation and run order: [ ]
- Independent preparation, sample, group, and injection identifiers: [ ]
- CI unit of independence and handling of unbalanced groups: [ ]
- Prior knowledge or development data used in place of a test, with justification: [ ]
4. Materials
| Item | Identity / grade | Lot | Assigned value and uncertainty | Expiry |
|---|---|---|---|---|
| Reference material | [ ] | [ ] | [ ] | [ ] |
| Impurity standards | [ ] | [ ] | [ ] | [ ] |
| Blank / placebo matrix | [ ] | [ ] | — | [ ] |
5. Sample and solution handling
- Preparation procedure and dilution scheme: [ ]
- Solution stability window to be demonstrated: [ ]
- Storage conditions: [ ]
6. Specificity and stability-indicating properties
- Interferences to be challenged: [ ]
- Forced degradation conditions, if a stability-indicating claim is made: [ ]
- Orthogonal procedure, if used, and its accuracy: [ ]
7. Robustness (normally development, ICH Q14)
| Parameter | Nominal | Range varied | Effect assessed on |
|---|---|---|---|
| [ ] | [ ] | [ ] | [ ] |
8. Statistical treatment
- Software, version, and how calculations are verified: [ ]
- Handling of outliers, stated in advance: [ ]
- Scripts to be used and their output retained as records: [ ]
9. Deviations and data integrity
- Deviation identification, assessment and approval route: [ ]
- All results will be reported, including out-of-criteria values: [ ] confirmed
- Raw data location, audit trail, and review: [ ]
10. Approvals
| Role | Name | Signature | Date |
|---|---|---|---|
| Author | |||
| Technical reviewer | |||
| Quality unit |
Author: K-Dense-AI, Scientific agent skills. License: MIT.
Shown here with formatting for the web. Keep the author and license notice when you reuse it.