medical-device-software (ra qm team) (Alireza Rezvani skills and agents) (medical device software) (4476)
Use for any question about the software inside a medical device, SaMD or regulated health app - which IEC 62304 safety class (A/B/C) it is and how much process and documentation that class needs, what to record about open-source or third-party libraries (SOUP, SBOM), trace matrix and release testing, IEC 81001-5-1 security, or the FDA documentation level and 524B cyber-device duties. Checks the us
Front matter
name: medical-device-software
description: Use for any question about the software inside a medical device, SaMD or regulated health app - which IEC 62304 safety class (A/B/C) it is and how much process and documentation that class needs, what to record about open-source or third-party libraries (SOUP, SBOM), trace matrix and release testing, IEC 81001-5-1 security, or the FDA documentation level and 524B cyber-device duties. Checks the user's files with four scripts that cite the clause.
argument-hint: "[software inventory CSV | lifecycle assessment CSV | SOUP register CSV + SBOM | trace matrix CSV]"
license: MIT
metadata:
version: 1.0.0
build_pattern: "Four deterministic stdlib scripts with blocking exit codes (IEC 62304 4.3 classifier with FDA documentation level and 524B cyber-device check, class-scoped lifecycle gap check with IEC 81001-5-1, SOUP register and SBOM cross-check, trace matrix release gate); clause claims labelled primary-verified, secondary-agreed or unverified"
distinct_from: "mdr-745-specialist (MDR device class, technical documentation); fda-consultant-specialist (submission pathway); risk-management-specialist (ISO 14971 file); cra-readiness (CRA, which excludes medical devices); regulatory-affairs-head (strategy)"Medical Device Software
Portability: 4 stdlib scripts, no network. Fill CSVs, run, keep the output with the software file. Not a conformity assessment. IEC 62304 is paywalled: clause markers here come from two agreeing secondary sources (🟡) and your licensed copy prevails. A notified body or FDA reviewer can read a borderline call differently.
Software files fail review in the same places: a class claimed lower than the harm allows, an "external" risk control that lives in the same software system, a SOUP list with "latest" as the version and no anomaly review, a trace matrix with risk controls nobody tested, and security treated as an afterthought. Three classifications get confused, and they use different inputs:
| Question | Decided by | Assessed |
|---|---|---|
| IEC 62304 class A/B/C (which activities) | worst-case harm, clause 4.3 + A1 Fig. 3 | after risk controls external to the software system |
| FDA Basic / Enhanced (what you submit) | probable risk of death or serious injury | before any risk controls |
| FD&C Act 524B cyber device | software + any internet-capable path (USB counts) | not risk-based |
Workflow
# 1 - Classify: system and item classes, FDA level, cyber device?
python scripts/software_safety_classifier.py --inventory assets/software_inventory.example.csv
# 2 - Gap check: is every activity the class requires done, with evidence?
python scripts/lifecycle_gap_check.py --class B --security --assessment assets/lifecycle_assessment.example.csv
# 3 - SOUP: identified, specified, anomaly lists reviewed, in the SBOM?
python scripts/soup_register_check.py --register assets/soup_register.example.csv --sbom assets/sbom.example.cdx.json --cyber-device
# 4 - Release: every requirement tested, every risk control verified?
python scripts/trace_matrix_check.py --matrix assets/trace_matrix.example.csv --class C --releaseClass first: steps 2 to 4 take the class from step 1. --template prints an empty input; lifecycle_gap_check.py --list --class X prints the required ids.
The gates block on (exit 4)
- A claimed class below what the harm allows, or an item below its system without a segregation rationale — 62304 4.3.
- An external risk control used to lower the class that is not itself verified — 62304 4.3 (A1).
- A required activity NOT MET, or NA where the clause is not conditional — the class table (A1 Table A.1).
- A SOUP item with no exact version (8.1.2), no stated requirements (5.3.3/5.3.4) or no anomaly-list review (7.1.3) for class B/C, or past end of support with no plan.
- A class B/C risk control with no hazard or no passing test (7.3.1, 7.3.3); with
--release, any untested requirement or open failed result without an anomaly record (5.7, 5.8). - A cyber device with no vulnerability monitoring on a SOUP item — 524B(b)(1).
Hard rules
- Unassessed is not MET. The gap check refuses a file that skips a required id.
- Unclassified is class C. Unknown inputs never round down.
- Severity decides the class, not probability. Only verified external controls lower it.
- Class A still tests. Software system testing (5.7) applies to every class since A1.
- Mark the confidence. 🟢 primary text checked · 🟡 secondary sources agree · 🔴 not verified. EN 62304 and EN IEC 81001-5-1 are not confirmed as cited in the OJ under the MDR; never claim presumption of conformity without checking the current list.
- Never sign or submit. The scripts prepare evidence; the manufacturer's named people approve the class, the release and the submission.
Scripts
| Script | Role | Exit codes |
|---|---|---|
scripts/software_safety_classifier.py | 62304 4.3 class per system and item, segregation, FDA documentation level, 524B cyber device | 0 classified · 2 findings · 3 bad input · 4 blocked |
scripts/lifecycle_gap_check.py | 62304 activities by class (+4.4 legacy), 81001-5-1 activities with --security | 0 ready · 2 gaps · 3 · 4 blocked |
scripts/soup_register_check.py | 8.1.2, 5.3.3/5.3.4, 7.1.3, end of support, 81001-5-1 risk-transfer category, SBOM cross-check (CycloneDX/SPDX) | 0 pass · 2 · 3 · 4 blocked |
scripts/trace_matrix_check.py | system → software requirement → test → result, risk control → hazard, release state | 0 pass · 2 · 3 · 4 blocked |
All support --help, --sample, --template and --output json.
References and assets
- [
references/classification_and_documentation_levels.md](references/classification_and_documentation_levels.md) — 62304 class decision path, external controls, segregation, FDA Basic/Enhanced, 524B, EU status, Edition 2 (10 sources) - [
references/lifecycle_requirements_by_class.md](references/lifecycle_requirements_by_class.md) — every clause by class, legacy software, regulatory standing (7 sources) - [
references/secure_lifecycle_81001_5_1.md](references/secure_lifecycle_81001_5_1.md) — 81001-5-1 clause map, ISH1:2025 risk transfer, mapping to 524B and MDCG 2019-16 (7 sources) - [
references/soup_and_traceability.md](references/soup_and_traceability.md) — SOUP evidence by class, SBOM, what reviewers check in a trace matrix (8 sources) assets/*.example.csv,assets/sbom.example.cdx.json— input formats, generated from each script's--sample
Author: alirezarezvani, Alireza Rezvani skills and agents. License: MIT.
Shown here with formatting for the web. Keep the author and license notice when you reuse it.
Related entries
- cs-device-software-lead
- Classification: IEC 62304 safety class, FDA documentation level, 524B cyber device
- medical-device-software (ra qm team) (Alireza Rezvani skills and agents) (medical device software) (4472)
- ISO Regulatory Requirements for Medical Devices
- SOUP, SBOM and traceability: where software files fail review
- IEC 81001-5-1: the security lifecycle on top of IEC 62304
There are more like this in the members library
The Claude Code library holds 13,843 entries. Members can search all of them by meaning and read every one in full.